Enterasys Networks 9034313-07 manual Set rmon alarm status

Models: 9034313-07

1 872
Download 872 pages 24.54 Kb
Page 467
Image 467

 

 

set rmon alarm status

 

 

 

 

startup rising

(Optional) Specifies the type of alarm generated when this event is first

 

falling either

enabled as:

 

 

• Rising ‐ Sends alarm when an RMON event reaches a maximum

 

 

threshold condition is reached, for example, more than 30 collisions

 

 

per second.

 

 

• Falling ‐ Sends alarm when RMON event falls below a minimum

 

 

threshold condition, for example when the network is behaving

 

 

normally again.

 

 

• Either ‐ Sends alarm when either a rising or falling threshold is

 

 

reached.

 

 

 

 

rthresh rthresh

(Optional) Specifies a minimum threshold for causing a rising alarm.

 

 

 

 

fthresh fthresh

Specifies a maximum threshold for causing a falling alarm.

 

 

 

 

revent revent

Specifies the index number of the RMON event to be triggered when the

 

 

rising threshold is crossed.

 

 

 

 

fevent fevent

Specifies the index number of the RMON event to be triggered when the

 

 

falling threshold is crossed.

 

 

 

 

owner owner

(Optional) Specifies the name of the entity that configured this alarm

 

 

entry.

 

 

 

Defaults

interval ‐ 3600 seconds

type ‐ absolute

startup ‐ rising

rthresh ‐ 0

fthresh ‐ 0

revent ‐ 0

fevent ‐ 0

owner ‐ monitor

Mode

Switch command, read‐write.

Example

This example shows how to configure a rising RMON alarm. This entry will conduct monitoring of the delta between samples every 30 seconds:

C3(rw)->set rmon alarm properties 3 interval 30 object 1.3.6.1.4.1.5624.1.2.29.1.2.1.0 type delta rthresh 1 revent 2 owner Manager

set rmon alarm status

Use this command to enable an RMON alarm entry. An alarm is a notification that a statistical sample of a monitored variable has crossed a configured threshold.

Syntax

set rmon alarm status index enable

SecureStack C3 Configuration Guide 15-11