set inlinepower trap

Usage

The threshold is expressed as a percentage of the available PoE power. When this threshold is reached, a trap will be sent if traps are enabled with the set inlinepower trap command.

Example

This example shows how to set the power threshold to 90 on module/unit 1:

C3(su)->set inlinepower threshold 90 1

set inlinepower trap

Use this command to enable or disable the sending of an SNMP trap message for a unit or module whenever the status of its ports changes, or whenever the unit’s power usage threshold is crossed.

Syntax

set inlinepower trap {disable enable} module-number

Parameters

disable enable Disables or enables inline power trap messaging.

module‐number

Specifies the module or unit on which to disable or enable trap messaging.

Defaults

Sending of traps is disabled by default.

Mode

Switch command, read‐write.

Usage

The module’s or unit’s power usage threshold must be set using the set inlinepower threshold command as described on page 5‐2.

Example

This example shows how to enable inline power trap messaging on module 1:

C3(su)->set inlinepower trap enable 1

set inlinepower detectionmode

Use this command to specify the method the switch will use to detect PDs (powered devices) connected to its ports.

Syntax

set inlinepower detectionmode {auto ieee)

SecureStack C3 Configuration Guide 5-3