clear rmon alarm

Parameters

index

Specifies an index number for this entry. Maximum number or entries is

 

50. Maximum value is 65535.

 

 

enable

Enables this alarm entry.

 

 

Defaults

None.

Mode

Switch command, read‐write.

Usage

An RMON alarm entry can be created using this command, configured using the set rmon alarm properties command (“set rmon alarm properties” on page 15‐10), then enabled using this command. An RMON alarm entry can be created and configured at the same time by specifying an unused index with the set rmon alarm properties command.

Example

This example shows how to enable RMON alarm entry 3:

C3(rw)->set rmon alarm status 3 enable

clear rmon alarm

Use this command to delete an RMON alarm entry.

Syntax

clear rmon alarm index

Parameters

index

Specifies the index number of entry to be cleared.

Defaults

None.

Mode

Switch command, read‐write.

Example

This example shows how to clear RMON alarm entry 1:

C3(rw)->clear rmon alarm 1