set spantree hello

Parameters

sid

(Optional) Resets the priority on a specific Spanning Tree. Valid values

 

are 0 4094. If not specified, SID 0 is assumed.

 

 

Defaults

If sid is not specified, priority will be reset on Spanning Tree 0.

Mode

Switch command, read‐write.

Example

This example shows how to reset the bridge priority on SID 1:

C3(su)->clear spantree priority 1

set spantree hello

Use this command to set the device’s Spanning Tree hello time, This is the time interval (in seconds) the device will transmit BPDUs indicating it is active.

Syntax

set spantree hello interval

Parameters

interval

Specifies the number of seconds the system waits before broadcasting a

 

bridge hello message (a multicast message indicating that the system is

 

active). Valid values are 1 10.

 

 

Defaults

None.

Mode

Switch command, read‐write.

Example

This example shows how to globally set the Spanning Tree hello time to 10 seconds:

C3(su)->set spantree hello 10

clear spantree hello

Use this command to reset the Spanning Tree hello time to the default value of 2 seconds.

Syntax

clear spantree hello

9-18 Spanning Tree Configuration

Page 288
Image 288
Enterasys Networks 9034313-07 manual Set spantree hello, Clear spantree hello