Enterasys Networks 9034313-07 Set pwa, Enable disable Enables or disables port web authentication

Models: 9034313-07

1 872
Download 872 pages 24.54 Kb
Page 816
Image 816

set pwa

Table 26-8 show pwa Output Details (Continued)

Output Field

What It Displays...

 

 

PWA Logo

Whether the Enterasys logo will be displayed or hidden at user login. Default state of

 

enabled (displayed) can be changed using the set pwa displaylogo command as

 

described in set pwa displaylogo” on page 26-72.

 

 

PWA Guest

Whether PWA guest user status is disabled or enabled with RADIUS or no

Networking Status

authentication. Default state of disabled can be changed using the set pwa

 

gueststatus command as described in set pwa gueststatus” on page 26-75.

 

 

PWA Guest Name

Guest user name for PWA enhanced mode networking. Default value of “guest” can

 

be changed using the set pwa guestname command as described in set pwa

 

guestname” on page 26-74.

 

 

PWA Guest

Guest user’s password. Default value of an empty string can be changed using the

Password

set pwa guestpassword command as described in set pwa guestpassword” on

 

page 26-75.

 

 

PWA Redirect Time

Time in seconds after login success before the user is redirected to the PWA home

 

page.

 

 

Port

PWA port designation.

 

 

Mode

Whether PWA is enabled or disabled on his port.

 

 

Auth Status

Whether or not the port state is disconnected, authenticating, authenticated, or held

 

(authentication has failed).

 

 

Quiet Period

Amount of time a port will be in the held state after a user unsuccessfully attempts to

 

log on to the network. Default value of 60 can be changed using the set pwa

 

quietperiod command as described in set pwa quietperiod” on page 26-76.

 

 

MaxReq

Maximum number of log on attempts allowed before transitioning the port to a held

 

state. Default value of 2 can be changed using the set pwa maxrequests command

 

as described in set pwa maxrequest” on page 26-77.

 

 

set pwa

Use this command to enable or disable port web authentication.

Syntax

set pwa {enable disable}

Parameters

enable disable Enables or disables port web authentication.

Defaults

None.

Mode

Switch command, read‐write.

Example

This example shows how to enable port web authentication:

C3(su)->set pwa enable

26-70 Authentication and Authorization Configuration

Page 816
Image 816
Enterasys Networks 9034313-07 manual Set pwa, Enable disable Enables or disables port web authentication