show sflow pollers

sFlow Configuration

Usage

A poller instance performs counter sampling on the data source to which it is configured. Refer to Sampling Mechanisms” on page 28‐2 for more information.

You must first associate a receiver/Collector in the sFlow Receivers Table with the poller instance, before configuring the polling interval.

When a receiver times out or is cleared from the sFlow Receivers Table, all poller and sampler instances associated with that receiver are also cleared from the switch’s configuration.

Example

The following example configures poller instances on ports ge.1.1 through ge.1.8 and associates them with receiver 1. Then, a polling interval of 240 seconds is configured.

C3(su)->set sflow port ge.1.1-8 poller 1

C3(su)->set sflow port ge.1.1-8 poller interval 240

show sflow pollers

Use this command to display information about configured poller instances.

Syntax

show sflow pollers

Parameters

None.

Defaults

None.

Mode

Switch command, read‐only.

Example

This example displays the output of this command.

C3(su)->show sflow pollers

Poller

Receiver

Poller

Data Source

Index

Interval

-----------

-------

-------

ge.1.1

1

240

ge.1.2

1

240

ge.1.3

1

240

ge.1.4

1

240

ge.1.5

1

240

ge.1.6

1

240

ge.1.7

1

240

ge.1.8

1

240

SecureStack C3 Configuration Guide 28-11

Page 859
Image 859
Enterasys Networks 9034313-07 manual Show sflow pollers, None