show sflow pollers sFlow Configuration
SecureStack C3 Configuration Guide 28-11
Usage
Apollerinstanceperformscountersamplingonthedatasourcetowhichitisconfigured.Referto
SamplingMechanismsonpage 282formoreinformation.
Youmustfirstassociateareceiver/CollectorinthesFlowReceiversTab le withthepollerinstance,
beforeconfiguringthepollinginterval.
WhenareceivertimesoutorisclearedfromthesFlowReceiversTabl e,allpollerandsampler
instancesassociatedwiththatreceiverarealsoclearedfromtheswitch’sconfiguration.
Example
Thefollowingexampleconfigurespollerinstancesonportsge.1.1throughge.1.8andassociates
themwithreceiver1.Then,apollingintervalof240secondsisconfigured.
C3(su)->set sflow port ge.1.1-8 poller 1
C3(su)->set sflow port ge.1.1-8 poller interval 240
show sflow pollers
Usethiscommandtodisplayinformationaboutconfiguredpollerinstances.
Syntax
show sflow pollers
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
Thisexampledisplaystheoutputofthiscommand.
C3(su)->show sflow pollers
Poller Receiver Poller
Data Source Index Interval
----------- ------- -------
ge.1.1 1 240
ge.1.2 1 240
ge.1.3 1 240
ge.1.4 1 240
ge.1.5 1 240
ge.1.6 1 240
ge.1.7 1 240
ge.1.8 1 240