Enterasys Networks 9034313-07 manual Set sflow port poller, Owner, Port port

Models: 9034313-07

1 872
Download 872 pages 24.54 Kb
Page 858
Image 858

sFlow Configuration

set sflow port poller

 

 

 

 

owner

(Optional) Clear the owner identity string. Entries in the sFlow Receiver

 

 

Table without an identity string are considered unclaimed.

 

 

 

 

timeout

(Optional) Clear the timeout value of the specified entry.

 

 

 

 

port port

(Optional) Clear the UDP port on the receiver/Collector to which the

 

 

sample datagrams should be sent. The value is reset to the default of

 

 

6343.

 

 

 

Defaults

If no optional parameters are specified, the entire entry is cleared.

Mode

Switch command, read‐write.

Usage

You can clear the IP address, maximum datagram size, or UDP port without deleting an entry from the sFlow Receivers Table. If you clear the owner or timeout, the entire entry is cleared. If you enter only an entry index and none of the optional parameters, the entire entry is cleared.

Once an entry is cleared, all pollers and samplers associated with that receiver are also removed from the switch configuration.

Example

This example returns the maximum datagram size to the default of 1400 bytes for the Collector with index 1.

C3(su)->clear sflow receiver 1 maxdatagram

set sflow port poller

Use this command to configure poller instances on ports, or data sources.

Syntax

set sflow port port-stringpoller {index interval seconds}

Parameters

port‐string

Specifies the port or ports (data sources) on which the poller instance is

 

being configured.

 

 

index

Index number in the sFlow Receivers Table for the receiver/Collector

 

with which the poller instance is associated. The index can range from 1

 

to 8.

 

 

interval seconds

Specifies the polling interval, which can range from 0 to 86400 seconds.

 

A value of 0 disables counter sampling.

 

 

Defaults

The default interval value is 0 seconds, which disables counter sampling.

Mode

Switch command, read‐write.

28-10

Page 858
Image 858
Enterasys Networks 9034313-07 manual Set sflow port poller, Owner, Port port