Enterasys Networks 9034313-07 manual Clear arpinspection filter, Permit

Models: 9034313-07

1 872
Download 872 pages 24.54 Kb
Page 539
Image 539

clear arpinspection filter

C3(su)->clear arpinspection vlan 5 logging

C3(su)->show arpinspection vlan 5

 

 

Source MAC Validation

Disabled

 

Destination MAC Validation

Disabled

 

IP Address Validation

Disabled

 

Vlan Configuration Log Invalid

ACL Name

Static flag

----------------- ----------- -------------------------------- -----------

5

Disabled

Disabled

staticARP

Enabled

clear arpinspection filter

Use this command to remove an ARP ACL from a VLAN or from the switch, or to remove a permit rule from an existing ACL, or to change the status of static mapping to disabled.

Syntax

clear arpinspection filter name [permit ip host sender-ipaddrmac host sender-macaddr] [vlan vlan-range[static]

Parameters

name

Specifies the name of the ARP ACL.

permit

(Optional) Specifies that a permit rule is being deleted.

 

 

ip host sender‐ipaddr

Specifies the IP address in the rule being deleted.

 

 

mac host

Specifies the MAC address in the rule being deleted.

sender‐macaddr

 

 

 

vlan vlan‐range

(Optional) Specifies the VLAN or VLANs to which this command

 

should apply. Remove the ACL from the VLAN, if static is not specified

 

also.

 

 

static

(Optional) Specifies that static mapping should be disabled for this ARP

 

ACL for the specified VLAN or VLANs.

 

 

Defaults

If only the name is specified, the ACL is deleted from the switch.

Mode

Switch command, read‐write.

Usage

You can use this command to:

Remove a configured ARP ACL from the switch, or

Remove a permit rule from a configured ARP ACL, or

Remove the association of an ARP ACL with a VLAN or VLANs, or

Disable static mapping of an ARP ACL associated with a VLAN or VLANs. Use the set arpinspection filter command to create and assign an ARP ACL.

Use the show arpinspection access‐list command to display currently configured ARP ACLs.

SecureStack C3 Configuration Guide 17-29