clear spantree lpcapablepartner

Defaults

If no port‐string is specified, Loop Protect capability for link partners is displayed for all ports.

Mode

Switch command, read‐only.

Example

This example shows how to display the Loop Protect partner capability for ge.1.1:

C3(rw)->show spantree lpcapablepartner port ge.1.1

Link partner of port ge.1.1 is not LoopProtect-capable

clear spantree lpcapablepartner

Use this command to reset the Loop Protect capability of port link partners to the default state of false.

Syntax

clear spantree lpcapablepartner port-string

Parameters

port‐string

Specifies port(s) for which to clear their link partners’ Loop Protect

 

capability (reset to false).

 

 

Defaults

None.

Mode

Switch command, read‐write.

Example

This example shows how to reset the Loop Protect partner capability for ge.1.1:

C3(rw)->clear spantree lpcapablepartner ge.1.1

set spantree lpthreshold

Use this command to set the Loop Protect event threshold.

Syntax

set spantree lpthreshold value

Parameters

value

Specifies the number of events that must occur during the event

 

window in order to lock a port/SID. The default value is 3 events. A

 

threshold of 0 specifies that ports will never be locked.

 

 