show lldp

Step

Task

Command(s)

 

 

 

1.

Configure global system LLDP parameters

set lldp tx-interval

 

 

set lldp hold-multiplier

 

 

set lldp trap-interval

 

 

set lldp med-fast-repeat

 

 

clear lldp

2.Enable/disable specific ports to:

Transmit and process received LLDPDUs

Send LLDP traps

Send LLDP-MED traps

set/clear lldp port status set/clear lldp port trap set/clear lldp port med-trap

3.

Configure an ECS ELIN value for specific ports

set/clear lldp

port location-info

4.

Configure Network Policy TLVs for specific ports

set/clear

lldp

port network-policy

5.

Configure which optional TLVs should be sent by

set/clear

lldp

tx-tlv

specific ports. For example, if you configured an ECS ELIN and/or Network Policy TLVs, you must enable those optional TLVs to be transmitted on the specific ports.

show lldp

Use this command to display LLDP configuration information.

Syntax

show lldp

Parameters

None.

Defaults

None.

Mode

Switch command, read‐only.

Example

This example shows how to display LLDP configuration information.

C3(ro)->show lldp

: 30

Message Tx Interval

Message Tx Hold Multiplier

: 4

Notification Tx Interval

: 5

MED Fast Start Count

: 3

Tx-Enabled Ports

: ge.1.1-60; ge.2.1-24; ge.3.1-30; ge.4.1-12;

Rx-Enabled Ports

: ge.1.1-60; ge.2.1-24; ge.3.1-30; ge.4.1-12;

Trap-Enabled Ports

: ge.1.1-60; ge.2.1-24; ge.3.1-30; ge.4.1-12;

MED Trap-Enabled Ports

: ge.1.1-60; ge.2.1-24; ge.3.1-30; ge.4.1-12;