set lldp hold-multiplier

Defaults

None.

Mode

Switch command, read‐write.

Example

This example sets the transmit interval to 20 seconds.

C3(rw)->set lldp tx-interval 20

set lldp hold-multiplier

Use this command to set the time‐to‐live value used in LLDP frames sent by this device. The time‐ to‐live for LLDPDU data is calculated by multiplying the transmit interval by the hold multiplier value.

Syntax

set lldp hold-multiplier multiplier-val

Parameters

multiplier‐val

Specifies the multiplier to apply to the transmit interval to determine

 

the time‐to‐live value. Value can range from 2 to 10. Default value is 4.

 

 

Defaults

None.

Mode

Switch command, read‐write.

Example

This example sets the transmit interval to 20 seconds and the hold multiplier to 5, which will configure a time‐to‐live of 100 to be used in the TTL field in the LLDPDU header.

C3(rw)->set lldp tx-interval 20

C3(rw)->set lldp hold-multiplier 5

set lldp trap-interval

Use this command to set the minimum interval between LLDP notifications sent by this device. LLDP notifications are sent when a remote system change has been detected.

Syntax

set lldp trap-interval frequency

6-24 Discovery Protocol Configuration

Page 156
Image 156
Enterasys Networks 9034313-07 manual Set lldp hold-multiplier, Set lldp trap-interval