show port inlinepower

Parameters

auto

Specifies that the switch will use the standard 802.3af detection method

 

first. If that fails, then the switch will use the legacy (pre 802.3af

 

standard) capacitance method of detection.

 

 

ieee

Specifies that the switch will only use the standard 802.3af detection

 

method.

 

 

Defaults

Default detection mode is auto.

Mode

Switch command, read‐write.

Usage

This command is used to specify how the switch should detect PDs connected to its ports. The PoE hardware in the switches can use the IEEE standard 802.3af (resistor‐based) method or a proprietary method using capacitor detection.

If auto is configured, the switch will first use the IEEE resistor‐based detection method, and if that fails, the switch will use the capacitor‐based detection method. If ieee is configured, only the IEEE resistor‐based detection method will be used.

Example

This example sets the switch’s PD detection mode to IEEE standard 802.3af only.

C3(su)->set inlinepower detectionmode ieee

show port inlinepower

Use this command to display all ports supporting PoE.

Syntax

show port inlinepower [port-string]

Parameters

port‐string

(Optional) Displays information for specific PoE port(s).

Defaults

If not specified, information for all PoE ports will be displayed.

Mode

Switch command, read‐only.

Example

This example shows how to display PoE information for port ge.2.1. In this case, the port’s administrative state, PoE priority and class have not been changed from default values:

5-4 Configuring System Power and PoE