Enterasys Networks 9034313-07 manual Show macauthentication Output Details, Nopassword

Models: 9034313-07

1 872
Download 872 pages 24.54 Kb
Page 772
Image 772

show macauthentication

Parameters

port‐string

(Optional) Displays MAC authentication information for specific port(s).

 

For a detailed description of possible port‐string values, refer to Port String

 

Syntax Used in the CLI” on page 7‐1.

 

 

Defaults

If port‐string is not specified, MAC authentication information will be displayed for all ports.

Mode

Switch command, read‐only.

Example

This example shows how to display MAC authentication information for ge.2.1 through 8:

C3(su)->show macauthentication ge.2.1-8

 

 

MAC authentication:

 

- enabled

 

 

MAC user password:

 

- NOPASSWORD

 

Port username significant bits

- 48

 

 

Port

Port

Reauth

Auth

Auth

Reauthentications

-------

State

Period

Allowed

Allocated

 

--------

----------

--------

--------- -----------------

ge.2.1

disabled

3600

1

1

disabled

ge.2.2

disabled

3600

1

1

disabled

ge.2.3

disabled

3600

1

1

disabled

ge.2.4

disabled

3600

1

1

disabled

ge.2.5

disabled

3600

1

1

disabled

ge.2.6

disabled

3600

1

1

disabled

ge.2.7

disabled

3600

1

1

disabled

ge.2.8

disabled

3600

1

1

disabled

Table 26‐3 provides an explanation of the command output.

Table 26-3 show macauthentication Output Details

Output Field

What It Displays...

 

 

MAC authentication

Whether MAC authentication is globally enabled or disabled. Set using the set

 

macauthentication command as described in set macauthentication” on

 

page 26-28.

 

 

MAC user password

User password associated with MAC authentication on the device. Set using the set

 

macauthentication password command as described in set macauthentication

 

password” on page 26-28.

 

 

Port username

Number of significant bits in the MAC addresses to be used starting with the left-most

significant bits

bit of the vendor portion of the MAC address. The significant portion of the MAC

 

address is sent as a user-name credential when the primary attempt to authenticate

 

the full MAC address fails. Any other failure to authenticate the full address, (i.e.,

 

authentication server timeout) causes the next attempt to start once again with a full

 

MAC authentication. Default value of 48 can be changed with the set

 

macauthentication significant-bits command.

 

 

Port

Port designation. For a detailed description of possible port-stringvalues, refer to

 

Port String Syntax Used in the CLI” on page 7-1.

 

 

Port State

Whether or not MAC authentication is enabled or disabled on this port.

26-26 Authentication and Authorization Configuration

Page 772
Image 772
Enterasys Networks 9034313-07 manual Show macauthentication Output Details, Nopassword