set switch

Parameters

unit

(Optional) Specifies the switch unit ID, an integer ranging from 1 to 8.

Defaults

None.

Mode

Switch command, read‐only.

Example

This example shows how to display data and error information on stack ports:

C3(ro)->show switch stack-ports

 

------------RX

 

 

 

Data------------

TX--------------

 

Stacking

Error

Total

Data

Error

Total

Switch

Rate

Rate

Rate

Rate

Port

(Mb/s)

(Errors/s)

Errors

(Mb/s)

(Errors/s)

Errors

1------

----------

------

----------

----------

------

----------

--------

Up

0

0

0

0

0

0

 

Down

0

0

0

0

0

0

set switch

Use this command to assign a switch ID, to set a switch’s priority for becoming the management switch if the previous management switch fails, or to change the switch unit ID for a switch in the stack.

Syntax

set switch {unit [priority value renumber newunit]}

Parameters

unit

Specifies a unit number for the switch. Value can range from 1 to 8.

priority value

Specifies a priority value for the unit. Valid values are 1 to 15 with higher

 

values assigning higher priority.

 

 

 

 

 

 

 

renumber newunit

Specifies a new number for the unit.

 

 

 

 

 

 

Note: This number must be a previously unassigned unit ID number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defaults

None.

Mode

Switch command, read‐write.

SecureStack C3 Configuration Guide 2-9