Enterasys Networks 9034313-07 Set port inlinepower, Admin off auto, Priority critical, High low

Models: 9034313-07

1 872
Download 872 pages 24.54 Kb
Page 131
Image 131

 

 

 

 

 

 

set port inlinepower

C3(su)->show port inlinepower ge.2.1

 

 

 

Port

Type

Admin

Oper

Priority

Class

Power(W)

----

----

-----

----

--------

-----

--------

ge.2.1

wireless

auto

searching

low

0

15.4

set port inlinepower

Use this command to configure PoE parameters on one or more ports.

Syntax

set port inlinepower port-string{[admin {off auto}] [priority {critical high low}] [type type]}

Parameters

port‐string

Specifies the port(s) on which to configure PoE.

admin off auto

Sets the PoE administrative state to off (disabled) or auto (on).

 

 

priority critical

Sets the port(s) priority for the PoE allocation algorithm to critical

high low

(highest), high or low.

 

 

type type

Specifies a string describing the type of device connected to a port.

 

 

Defaults

None.

Mode

Switch command, read‐write.

Example

This example shows how to enable PoE on port ge.3.1 with critical priority:

C3(su)->set port inlinepower ge.3.1 admin auto priority critical

SecureStack C3 Configuration Guide 5-5

Page 131
Image 131
Enterasys Networks 9034313-07 manual Set port inlinepower, Admin off auto, Priority critical, High low, Type type