show spantree operedge

Parameters

 

 

 

 

 

port‐string

Specifies port(s) on which to reset edge port status. For a detailed

 

 

description of possible port‐string values, refer to Port String Syntax Used

 

 

in the CLI” on page 7‐1.

 

 

 

Defaults

 

 

None.

 

Mode

 

Switch command, read‐write.

Example

This example shows how to reset ge.1.11 as a non‐edge port:

C3(su)->clear spantree adminedge ge.1.11

show spantree operedge

Use this command to display the Spanning Tree edge port operating status for a port.

Syntax

show spantree operedge [port port-string]

Parameters

port port‐string

Displays edge port operating status for specific port(s).

Defaults

If port‐string is not specified, edge port operating status will be displayed for all Spanning Tree ports.

Mode

Switch command, read‐only.

Example

This example shows how to display the edge port status for ge.2.7:

C3(rw)->show spantree operedge port ge.2.7

Port ge.2.7 has a Port Oper Edge of Edge-Port

SecureStack C3 Configuration Guide 9-41

Page 311
Image 311
Enterasys Networks 9034313-07 manual Show spantree operedge, This example shows how to reset ge.1.11 as a non‐edge port