set lldp med-fast-repeat

 

Parameters

 

 

 

 

 

 

 

frequency

Specifies the minimum time between LLDP trap transmissions, in

 

 

 

seconds. The value can range from 5 to 3600 seconds. The default

 

 

 

value is 5 seconds.

 

 

 

 

 

Defaults

 

 

 

None.

 

 

Mode

 

 

Switch command, read‐write.

Example

This example sets the minimum interval between LLDP traps to 10 seconds.

C3(rw)->set lldp trap-interval 10

set lldp med-fast-repeat

Network connectivity devices transmit only LLDP TLVs in LLDPDUs until they detect that an LLDP‐MED endpoint device has connected to a port. At that point, the network connectivity device starts sending LLDP‐MED TLVs at a fast start rate on that port. Use this command to set the number of successive LLDPDUs (with LLDP‐MED TLVs) to be sent for one complete fast start interval.

Syntax

set lldp med-fast-repeat count

Parameters

count

Specifies the number of fast start LLDPDUs to be sent when an

 

LLDP‐MED endpoint device is detected. Value can range from 1 to

 

10. Default is 3.

 

 

Defaults

None.

Mode

Switch command, read‐write.

Example

This example sets the number of fast start LLDPDUs to be sent to 4.

C3(rw)->set lldp med-fast-repeat 4