Enterasys Networks 9034313-07 Show system, This example shows how to display system information

Models: 9034313-07

1 872
Download 872 pages 24.54 Kb
Page 75
Image 75

show system

Mode

Switch command, read‐write.

Example

This example shows how to set the method used to acquire a network IP address to DHCP.

C3(su)->set ip protocol dhcp

show system

Use this command to display system information, including contact information, power and fan tray status and uptime.

Syntax

show system

Parameters

None.

Defaults

None.

Mode

Switch command, read‐only.

Example

This example shows how to display system information:

C3(su)->show system

System contact:

System location:

System name:

Switch 1

 

--------

PS2-Status

PS1-Status

Ok----------

----------

Not Installed and/or Not Operating

Fan1-Status

Fan2-Status

Ok-----------

-----------

Ok

Temp-Alarm

-----------

off

Thermal Threshold: 58%

Temp alarm max threshold: 100%

Temp alarm trap: disabled

Temp alarm syslog: disabled

Uptime d,h:m:s

Logout

0,20:36:49--------------

-------

0 min

SecureStack C3 Configuration Guide 3-13