set system enhancedbuffermode

Defaults

None.

Mode

Switch command, read‐write.

Example

This example shows how to display enhanced buffer mode status:

C3(su)->show system enhancedbuffermode enable

Disable

Optimized system buffer distribution

set system enhancedbuffermode

Use this command to enable or disable enhanced buffer mode, which optimizes buffer distribution into a single CoS queue operation for standalone switches or non‐stacked switches. Executing this command will reset the switch, so the system prompts you to confirm whether you want to proceed.

Syntax

set system enhancedbuffermode {enable disable}

Parameters

enable disable Enables or disables enhanced buffer mode.

Defaults

None.

Mode

Switch command, read‐write.

Example

This example shows how to enable enhanced buffer mode:

C3(su)->set system enhancedbuffermode enable

Changes in the enhanced buffer mode will require resetting this unit.

Are you sure you want to continue? (y/n)

set system temperature

Use this command to set the system high temperature threshold limit and the high temperature alert parameters, on the platforms that support this feature.

Syntax

set system temperature {[syslog enable disable] [trap enable disable] [overtemp-threshold value]}

3-18 Basic Configuration

Page 80
Image 80
Enterasys Networks 9034313-07 manual Set system enhancedbuffermode, Set system temperature