Use this command to display the configuration persistence mode setting.

Syntax

show snmp persistmode

Parameters

None.

Defaults

None.

Mode

Switch command, read‐only.

Usage

By default, the mode is set to “auto save,” which automatically saves configuration changes at specific intervals. If the mode is set to “manual,” configuration commands are never automatically saved. In order to make configuration changes persistent when the mode is manual, the save config command must be issued as described in Configuration Persistence Mode” on page 3‐39.

Example

This example shows how to display the configuration persistence mode setting. In this case, persistence mode is set to “manual”, which means configuration changes are not being automatically saved.

C3(su)->show snmp persistmode persistmode is manual

set snmp persistmode

Use this command to set the configuration persistence mode, which determines whether user‐ defined configuration changes are saved automatically, or require issuing the save config command. See Configuration Persistence Mode” on page 3‐39 for more information.