Enterasys Networks 9034313-07 manual Clear radius accounting, Retries, Timeout, Counter

Models: 9034313-07

1 872
Download 872 pages 24.54 Kb
Page 757
Image 757

clear radius accounting

timeout timeout Sets the maximum amount of time (in seconds) to establish contact with a specified RADIUS accounting server before timing out. Valid timeout values are 1 30.

server ip_address port server‐secret

Specifies the accounting server’s:

IP address

UDP authentication port (0 65535)

server‐secret (Read‐Write password to access this accounting server. Device will prompt for this entry upon creating a server instance, as shown in the example below.)

Mode

Switch command, read‐write.

Defaults

None.

Examples

This example shows how to enable the RADIUS accounting client for authenticating with the accounting server at IP address 10.2.4.12, UDP authentication port 1800. As previously noted, the “server secret” password entered here must match that already configured as the Read‐Write (rw) password on the RADIUS accounting server:

C3(su)->set radius accounting server 10.2.4.12 1800

Enter secret:

Re-enter secret:

This example shows how to set the RADIUS accounting timeout to 30 seconds:

C3(su)->set radius accounting timeout 30

This example shows how to set RADIUS accounting retries to 10:

C3(su)->set radius accounting retries 10

clear radius accounting

Use this command to clear RADIUS accounting configuration settings.

Syntax

clear radius accounting {server ip-addressretries timeout counter}

Parameters

server ip‐address

Clears the configuration on one or more accounting servers.

retries

Resets the retries to the default value of 3.

 

 

timeout

Resets the timeout to 5 seconds.

 

 

counter

Clears counters.

 

 

Mode

Switch command, read‐write.

SecureStack C3 Configuration Guide 26-11

Page 757
Image 757
Enterasys Networks 9034313-07 Clear radius accounting, This example shows how to set Radius accounting retries to, Retries