ping ipv6 interface

 

Parameters

 

 

 

 

 

 

 

ipv6‐addr

Specifies the global IPv6 address of the system to ping. Enter the address in

 

 

 

the form documented in RFC 4291, with the address specified in

 

 

 

hexadecimal using 16‐bit values between colons.

 

 

 

 

 

 

size num

(Optional) Specifies the size of the datagram packet. The value of num can

 

 

 

range from 48 to 2048 bytes.

 

 

 

 

 

Defaults

 

 

 

None.

 

 

Mode

Router privileged exec: C3(su)‐>router#

Router user exec: C3(su)‐>router>

Usage

Use this command to determine whether another computer is on the network. To use this command, configure the switch for network (in‐band) connection. The source and target devices must have the ping utility enabled and running on top of TCP/IP.

The switch can be pinged from any IP workstation with which the switch is connected through the default VLAN (VLAN 1), as long as there is a physical path between the switch and the workstation. The terminal interface sends three pings to the target station.

Examples

This example shows output from a successful ping to IPv6 address 2001:0db8:1234:5555::1234:1.

C3(su)->router#ping ipv6 2001:0db8:1234:5555::1234:1

Send count=3, Receive count=3 from 2001:DB8:1234:5555::1234:1

Average round trip time = 1.00 ms

This example shows output from an unsuccessful ping to IPv6 address 2001:0db8:1234:5555::1234:1.

C3(su)->ping ipv6 2001:0db8:1234:5555::1234:1 no answer from 2001:DB8:1234:5555::1234:1

ping ipv6 interface

Use this command to test routing network connectivity by sending IP ping requests.

Syntax

ping ipv6 interface {vlan vlan-idtunnel tunnel-idloopback loop-id}{link-local-address ipv6-lladdr ipv6-addr} [size num]

Parameters

vlan vlan‐id

Specifies a VLAN interface as the source.

tunnel tunnel‐id

Specifies a tunnel interface as the source.

 

 

loopback loop‐id

Specifies a loopback interface as the source.

 

 

link‐local‐address

Specifies a link‐local IPv6 address to ping.

ipv6‐lladdr

 

 

 

SecureStack C3 Configuration Guide 22-7