clear snmp notifyfilter

included

(Optional) Specifies that subtree is included or excluded.

excluded

 

 

 

volatile

(Optional) Specifies a storage type.

nonvolatile

 

 

 

Defaults

If not specified, mask is not set.

If not specified, subtree will be included.

If storage type is not specified, nonvolatile (permanent) will be applied.

Mode

Switch command, read‐write.

Usage

See About SNMP Notify Filters” on page 8‐29 for more information about notify filters.

Example

This example shows how to create an SNMP notify filter called “pilot1” with a MIB subtree ID of 1.3.6:

C3(su)->set snmp notifyfilter pilot1 subtree 1.3.6

clear snmp notifyfilter

Use this command to delete an SNMP notify filter configuration.

Syntax

clear snmp notifyfilter profile subtree oid-or-mibobject

Parameters

profile

Specifies an SNMP filter notify name to delete.

subtree oid‐or‐

Specifies a MIB subtree ID containing the filter to be deleted.

mibobject

 

 

 

Defaults

None.

Mode

Switch command, read‐write.

Example

This example shows how to delete the SNMP notify filter “pilot1”:

C3(su)->clear snmp notifyfilter pilot1 subtree 1.3.6

SecureStack C3 Configuration Guide 8-35

Page 263
Image 263
Enterasys Networks 9034313-07 manual Clear snmp notifyfilter