set logging application

Parameters

 

 

 

 

 

mnemonic

(Optional) Displays severity level for one application configured for

 

 

logging. Mnemonics will vary depending on the number and types of

 

 

applications running on your system. Sample mnemonics and their

 

 

corresponding applications are listed in Table 14‐3 on page 14‐8.

 

 

Note: Mnemonic values are case sensitive and must be typed as they appear in

 

 

Table 14-3.

 

 

 

 

all

(Optional) Displays severity level for all applications configured for

 

 

logging.

 

 

 

Defaults

If no parameter is specified, information for all applications will be displayed.

Mode

Switch command, read‐only.

Example

This example shows how to display system logging information pertaining to the SNMP application.

C3(ro)->show logging application SNMP

Application

Current Severity Level

---------------------------------------------

90

SNMP

 

6

1(emergencies)

2(alerts)

3(critical)

4(errors)

5(warnings)

6(notifications)

7(information)

8(debugging)

 

Table 14‐2 provides an explanation of the command output.

Table 14-2 show logging application Output Details

Output Field

What it displays...

 

 

Application

A mnemonic abbreviation of the textual description for

 

applications being logged.

 

 

Current Severity Level

Severity level at which the server is logging messages for the

 

listed application. This range (from 1 to 8) and its associated

 

severity list is shown in the CLI output. For a description of these

 

entries, which are set using the set logging application

 

command, refer to set logging application” on page 14-7.

 

 

set logging application

Use this command to set the severity level of log messages for one or all applications.

Syntax

set logging application {[mnemonic all]} [level level]

SecureStack C3 Configuration Guide 14-7

Page 421