Using and Configuring WebView

Use clear config to clear configuration parameters without clearing stack unit IDs. This command WILL NOT clear stack parameters and avoids the process of re‐numbering the stack.

Use clear config all when it is necessary to clear all configuration parameters, including stack unit IDs (if applicable) and switch priority values.

Use the clear ip address command to clear the IP address.

Configuration parameters and stacking information can also be cleared on the master unit only by selecting option 10 (restore configuration to factory defaults) from the boot menu on switch startup. This selection will leave stacking priorities on all other units, if applicable.

Example

This example shows how to clear configuration parameters (including stacking parameters, if applicable):

C3(su)->clear config all

Using and Configuring WebView

Purpose

By default, WebView (The Enterasys Networks embedded web server for switch configuration and management tasks) is enabled on TCP port number 80 on the SecureStack C3 switch. You can verify WebView status, and enable or disable WebView using the commands described in this section. WebView can also be securely used over SSL port 443, if SSL is enabled on the switch. By default, SSL is disabled.

To use WebView, type the IP address of the switch in your browser. To use WebView over SSL, type in https:// then the IP address of the switch. For example, https://172.16.2.10.

Commands

For information about...

Refer to page...

 

 

show webview

3-52

 

 

set webview

3-53

 

 

show ssl

3-53

 

 

set ssl

3-54

 

 

show webview

Use this command to display WebView status.

Syntax

show webview

Parameters

None.

3-52 Basic Configuration

Page 114
Image 114
Enterasys Networks 9034313-07 Using and Configuring WebView, Show webview, Use this command to display WebView status