set system login

set system login

Use this command to create a new user login account, or to disable or enable an existing account. The SecureStack C3 switch supports up to 16 user accounts, including the admin account, which cannot be deleted.

Syntax

set system login username {super-user read-write read-only} {enable disable}

Parameters

username

Specifies a login name for a new or existing user. This string can be a

 

maximum of 80 characters, although a maximum of 16 characters is

 

recommended for proper viewing in the show system login display.

super‐user read‐write read‐only

Specifies the access privileges for this user.

enable disable Enables or disables the user account.

Defaults

None.

Mode

Switch command, super user.

Usage

Login accounts, including the admin user account, can be locked out after multiple failed attempts to log in to the system. Refer to show system lockout” on page 3‐7 and set system lockout” on page 3‐8 for more information about lockout parameters.

If the admin user account has been locked out, you must wait until the configured lockout time period has expired or you can power cycle the switch to reboot it, which will re‐enable the admin user account.

Example

This example shows how to enable a new user account with the login name “netops” with super user access privileges:

C3(su)->set system login netops super-user enable

clear system login

Use this command to remove a local login user account.

Syntax

clear system login username

3-4 Basic Configuration

Page 66
Image 66
Enterasys Networks 9034313-07 manual Set system login, Clear system login, Super‐user read‐write read‐only