set spantree lpwindow

Defaults

None.

Mode

Switch command, read‐write.

Example

This example shows how to reset the Loop Protect event threshold to the default of 3:

C3(rw)->clear spantree lpthreshold

set spantree lpwindow

Use this command to set the Loop Protect event window value in seconds.

Syntax

set spantree lpwindow value

Parameters

value

Specifies the number of seconds that comprise the period during which

 

Loop Protect events are counted. The default event window is 180

 

seconds.

 

 

Defaults

None.

Mode

Switch command, read‐write.

Usage

The Loop Protect Window is a timer value, in seconds, that defines a period during which Loop Protect events are counted. The default value is 180 seconds. If the timer is set to 0, the event counter is not reset until the Loop Protect event threshold is reached. If the threshold is reached, that constitutes a loop protection event.

Example

This example shows how to set the Loop Protect event window to 120 seconds:

C3(rw)->set spantree lpwindow 120

show spantree lpwindow

Use this command to display the current Loop Protect event window value.

Syntax

show spantree lpwindow

SecureStack C3 Configuration Guide 9-49

Page 319
Image 319