show snmp notify

Parameters

 

 

 

 

 

port‐string

(Optional) Enable or disable the new MAC addresses trap function on

 

 

specific ports.

 

 

 

 

enable disable

Enable or disable the new MAC addresses trap function. If entered

 

 

without the port‐string parameter, enables or disables the function

 

 

globally. When entered with the port‐string parameter, enables or

 

 

disables the function on specific ports.

 

 

 

Defaults

If port‐string is not specified, the trap function is set globally.

Mode

Switch mode, read‐write.

Usage

This command enables and disables sending SNMP trap messages when a new source MAC address is detected by a port. If the port is a CDP port, however, traps for new source MAC addresses will not be sent.

The default mode is disabled globally and per port.

Example

This example enables the trap function globally and then on Gigabit Ethernet ports 1 through 5 in unit/slot 1.

C3(rw)->set newaddrtrap enable

C3(rw)->set newaddrtrap ge.1.1-5 enable

show snmp notify

Use this command to display the SNMP notify configuration, which determines the management targets that will receive SNMP notifications.

Syntax

show snmp notify [notify] [volatile nonvolatile read-only]

Parameters

notify

(Optional) Displays notify entries for a specific notify name.

volatile

(Optional) Displays notify entries for a specific storage type.

nonvolatile read‐

 

only

 

 

 

Defaults

If a notify name is not specified, all entries will be displayed.

If volatile, nonvolatile, or read‐only are not specified, all storage type entries will be displayed.

Mode

Switch command, read‐only.

SecureStack C3 Configuration Guide 8-31