show snmp notify
SecureStack C3 Configuration Guide 8-31
Parameters
Defaults
Ifportstringisnotspecified,thetrapfunctionissetglobally.
Mode
Switchmode,readwrite.
Usage
ThiscommandenablesanddisablessendingSNMPtrapmessageswhenanewsourceMAC
addressisdetectedbyaport.IftheportisaCDPport,however,trapsfornewsourceMAC
addresseswillnotbesent.
Thedefaultmodeisdisabledgloballyandperport.
Example
ThisexampleenablesthetrapfunctiongloballyandthenonGigabitEthernetports1through5in
unit/slot1.
C3(rw)->set newaddrtrap enable
C3(rw)->set newaddrtrap ge.1.1-5 enable
show snmp notify
UsethiscommandtodisplaytheSNMPnotifyconfiguration,whichdeterminesthemanagement
targetsthatwillreceiveSNMPnotifications.
Syntax
show snmp notify [notify] [volatile | nonvolatile | read-only]
Parameters
Defaults
Ifanotifynameisnotspecified,allentrieswillbedisplayed.
Ifvolatile,nonvolatile,orreadonlyarenotspecified,allstoragetypeentrieswillbedisplayed.
Mode
Switchcommand,readonly.
portstring (Optional)EnableordisablethenewMACaddressestrapfunctionon
specificports.
enable|disable Enableordisable��thenewMACaddressestrapfunction.Ifentered
withouttheportstringparameter,enablesordisablesthefunction
globally.Whenenteredwiththeportstringparameter,enablesor
disablesthefunctiononspecificports.
notify (Optional)Displaysnotifyentriesforaspecificnotifyname.
volatile|
nonvolatile|read
only
(Optional)Displaysnotifyentriesforaspecificstoragetype.