COOLING ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS

Problem

 

Possible Cause

Action

 

Sublimation:

When

Ensure that foam gaskets are installed in

 

between window panes & in between the unit &

 

unconditioned saturated, outside air mixes with

 

the sleeve. Also, ensure that fresh air/exhaust

 

conditioned air, condensation forms on the cooler

 

vents (on applicable models) are in the closed

 

surfaces

 

Water "spitting"

 

position & are in tact

 

 

 

 

 

into room

 

 

Follow installation instructions to ensure that

 

Downward pitch of installation is too steep

downward pitch of installed unit is no less than

 

 

 

1/4" & no more than 3/8"

 

Restricted coil or dirty filter

Clean & advise customer of periodic cleaning &

 

maintenance needs of entire unit

 

 

 

Problem

Possible Cause

Action

 

Insufficient air circulation thru area to be air

Adjust louvers for best possible air circulation

 

conditioned

 

 

Excessive moisture

Oversized unit

Operate in "MoneySaver" position

 

Inadequate vapor barrier in building structure,

Advise customer

 

particularly floors

 

 

Problem

Possible Cause

Action

 

T-stat differential too narrow

Replace t-stat

T-stat short cycles

Plenum gasket not sealing, allowing discharge air

Check gasket. Reposition or replace as needed

to short cycle t-stat

 

 

Restricted coil or dirty filter

Clean & advise customer of periodic cleaning &

 

maintenance needs of entire unit

 

 

Problem

Possible Cause

Action

 

Anticipator (resistor) wire disconnected at t-stat

Refer to appropriate wiring diagram

 

or system switch

 

 

 

 

 

Prolonged off

 

Disconnect plus from outlet. Remove resistor

 

from bracket. Insert plug & depress "COOL"

cycles (automatic

 

Anticipator (resistor) shorted or open

& "FAN AUTOMATIC" buttons. Place t-stat to

operation)

 

warmest setting. Feel resistor for temperature. If

 

 

 

 

no heat, replace resistor

 

 

 

 

Partial loss of charge in t-stat bulb causing a wide

Replace t-stat

 

differential

 

Problem

Possible Cause

Action

 

Evaporator drain pan cracked or obstructed

Repair, clean or replace as required

 

 

 

 

Water in compressor area

Detach shroud from pan & coil. Clean & remove

 

old sealer. Reseal, reinstall & check

Outside water leaks

 

Obstructed condenser coil

Use pressure wash or biodegradable cleaning

 

 

agent to clean

 

 

 

Fan blade/slinger ring improperly positioned

Adjust fan blade to 1/2" of condenser coil

 

 

 

20