TROUBLESHOOTING CHART — HEATING

REFRIGERANT SYSTEM DIAGNOSIS – HEATING

Low Suction Pressure

High Suction Pressure

Low Head Pressure

High Head Pressure

Low Airflow

Outdoor Ambient Too High

Refrigerant

System

Outdoor Ambient Too High

Across Outdoor Coil

for Operation in Heating

Restriction

For Operation In Heating

Refrigerant System

Reversing Valve not

Reversing Valve not

Low Airflow Across

Restriction

Fully Seated

Fully Seated

Indoor Coil

Undercharged

Overcharged

Undercharged

Overcharged

Moisture in System

Defective Compressor

Defective Compressor

Noncondensables (air)

ELECTRICAL TROUBLESHOOTING CHART — HEAT PUMP

HEAT PUMP

SYSTEM COOLS WHEN

HEATING IS DESIRED.

Is Line Voltage

 

Is the Selector Switch

Present at the Solenoid

NO

Set for Heat?

 

 

YES

 

 

Is the Solenoid Coil Good?

NO

Replace the Solenoid Coil

 

 

YES

 

 

Reversing Valve Stuck

 

 

Replace the Reversing Valve

23

Page 23
Image 23
Friedrich 2007 service manual Troubleshooting Chart Heating, Electrical Troubleshooting Chart Heat Pump, Yes