Friedrich CP12F10, CP10F10 Troubleshooting Guide, Unit runs but poor cooling, Ineffective Cooling

Models: CP10F10 CP12F10

1 28
Download 28 pages 12.98 Kb
Page 18
Image 18
Troubleshooting Guide

Troubleshooting Guide

Unit runs but poor cooling.Ineffective CoolingTroubleshooting GuideManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

In general, possible trouble is classified in two kinds.

The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.

Unit runs but poor cooling.

Ineffective Cooling

Check cold air circulation for smooth flow.

Dirty indoor coil (heat exchanger)

Malfunction of fan.

Clogging of air filter.

Obstruction at air outlet.

Remove obstruction.

Check clogging in refrigera- tion circuit.

Repair clogging in refrigeration circuit.

Check outdoor coil (heat exchanger) and fan operation.

Check gas leakage.

Repair gas leak.

Replacement of unit if the unit is beyond repair.

Satisfactory operation with temperature difference of inlet & outlet air; 44~50°F (7~10°C)

Check heat load increase.

Clean condenser.

Not on separate circuit

Check inside gas pressure.

Adjust refrigerant charge.

Malfunction of compressor.

Replacement of compressor.