Disassembly
3. CAPACITOR
MODEL : TOUCH & REMOTE CONTROL TYPE MODEL
1. | Remove the control box. |
|
2. | Remove the screw which fasten control panel from |
|
| control box. |
|
3. | Remove the screw which located in the front. |
|
4. | Open the bottom side of control box. |
|
5. | Remove the screw and the clamp which fastens |
|
| the capacitor. |
|
6. | Disconnect all the leads of capacitor terminals. |
|
7. | Figure 10 | |
| removal procedure, above. (See Figure 10) |
4. POWER CORD
1.Remove the control box.
2.Open the control box.
3.Disconnect the grounding screw from the control box.
4.Disconnect the 2 receptacles.
5.Remove a screw which fastens the clip cord.
(See Figure 11)
6. Remove the power cord. |
|
7. |
|
removal procedure, above. |
|
(Use only one |
|
connection.) |
|
8. If the supply cord of this appliance is damaged, it | Figure 11 |
must be replaced by the special cord. (The |
|
special cord means the cord which has the same |
|
specification marked on the supply cord attached at |
|
the unit.) |
|
Refrigerating Cycle
CAUTION: Discharge the refrigerant system using a FreonTM Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO
1.CONDENSER
1.Remove the cabinet.
2.Remove the 3 screws which fasten the
brace.
3. Remove the 3 screws which fasten the condenser and shroud.
4. After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.
5. Remove the condenser carefully.
6.
Figure 12