ADJUSTING THE DIRECTION OF AIR CIRCULATION

ADJUSTING THE DIRECTION OF AIR CIRCULATION

Adjust the up, down, left, and right AIR directions with the AIR DIRECTION buttons on the Remote Control Unit.

Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airflow-direction louvers have stopped moving.

Vertical Air Direction Adjustment

Press the SET button (Vertical) (Fig. 6 Q).

Each time the button is pressed, the air direction range will change as follows:

RDANGER!

Never place fingers or foreign objects in- side the outlet ports, since the internal fan operates at high speed and could cause personal injury.

1 Vertical Air Direction AdjustmentPress the SET button (Vertical) (Fig. 6 Q). 2 Types of Air flow Direction Setting:Horizontal Air Direction Adjustment 3 Press the SET button (Horizontal)(Fig. 6 R).En-9 4 Manual backgroundManual background 5 Manual backgroundManual background 6

Types of Air flow Direction Setting:

1,2,3 : During Cooling/Dry modes

1,2,3,4,5,6 : During Fan mode

The Remote Control Unit’s display does

 

not change.

1

 

2

3

4

5

6

Use the air direction adjustments within the ranges shown above.

The vertical airflow direction is set automatically as shown, in accordance with the type of operation selected.

During Cooling/Dry mode : Horizontal flow 1

During Fan mode

: Downward flow 5

During AUTO mode operation, for the first minute after beginning operation, airflow will be horizontal 1; the air direction cannot be adjusted during this pe- riod.

Direction 1 Manual backgroundManual background 2

Only the direction of the Air Flow Direction Louver changes; the direction of the Power Diffuser does not change.

Always use the Remote Control Unit’s SET button to adjust the vertical airflow louvers. Attempting to move them manually could result in improper op- eration; in this case, stop operation and restart. The louvers should begin to operate properly again.

During Cooling and Dry modes, do not move the vertical air direction louvers outside their proper operating range for the mode (1 - 3) and into the fan region (4 - 6); using the louvers in the fan region will cause moisture to condense near the air outlet, and wa- ter may drop onto the floor. During the Cooling/Dry modes, if the louvers are operated outside the range 1 - 3 for more than 30 minutes, they will be automatically returned to the 3range.

When used in a room with infants, chil- dren, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.

Horizontal Air Direction Adjustment

Press the SET button (Horizontal)(Fig. 6 R).

Each time the button is pressed, the air direction range will change as follows:

1 Manual backgroundManual background 2 Manual backgroundManual background 3 Manual backgroundManual background 4 Manual backgroundManual background 5

The remote control unit’s display does not change.