Friedrich MW12Y1F About Auto Changeover Operation, About Mode Operation, During Heating mode

Models: MR09Y1F MR12Y1F MW09Y1F MW12Y1F

1 46
Download 46 pages 28.65 Kb
Page 7
Image 7

OPERATION

About AUTO CHANGEOVER Operation

AUTO: ● When AUTO CHANGEOVER operation first selected, the fan will oper- ate at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode.

If the differance between thermostat setting and actual room tempera- ture is more than +4 °F Cooling

If the difference between thermostat setting and actual room tempera- ture is within ±4 °F Monitor operation

If the difference between thermostat setting and actual room tempera- ture is more than –4 °F Heating operation

When the air conditioner has adjusted your room’s temperature to near the thermostat setting, it will begin monitor operation. In the monitor operation mode, the fan will operate at low speed. If the room tem- perature subsequently changes, the air conditioner will once again select the appropriate operation (Heating, Cooling) to adjust the tem- perature to the value set in the thermostat.

(The monitor operation range is ±4 °F relative to the thermostat setting.)

If the mode automatically selected by the unit is not what you wish, select one of the mode operation (HEAT, COOL, DRY, FAN).

About Mode Operation

Heating: ● Use to warm your room.

When Heating mode is selected, the air conditioner will operate at very low fan speed for about 3 to 5 minutes, after which it will switch to the selected fan setting. This period of time is provided to allow the indoor unit to warm up before begin full operation.

When the room temperature is very low, frost may form on the outside unit, and its performance may be reduced. In order to remove such frost, the unit will automatically enter the defrost cycle from time to time. During Automatic Defrosting operation, the OPERATION indica- tor lamp (red) will flash, and the heat operation will be interrupted.

Cooling: ● Use to cool your room.

Dry: ● Use for gently cooling while dehumidifying your room.

You cannot heat the room during Dry mode.

During Dry mode, the unit will operate at low speed; in order to adjust room humidity, the indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when adjusting room humidity.

The fan speed cannot be changed manually when Dry mode has been selected.

Fan: ● Use to circulate the air throughout your room.

During Heating mode:

Set the thermostat to a temperature set- ting that is higher than the current room temperature. The Heating mode will not operate if the thermostat is set lower than the actual room temperature.

During Cooling/Dry mode:

Set the thermostat to a temperature set- ting that is lower than the current room temperature. The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature (in Cooling mode, the fan alone will oper- ate).

During Fan mode:

You can not use the unit to heat and cool your room.

En-6

Page 7
Image 7
Friedrich MW12Y1F About Auto Changeover Operation, About Mode Operation, During Heating mode, During Cooling/Dry mode

MR09Y1F MR12Y1F, MW09Y1F, MW12Y1F specifications

The Friedrich MW12Y1F, MW09Y1F, MR09Y1F, and MR12Y1F are part of a modern series of air conditioning systems designed for efficiency, reliability, and advanced comfort control. These units are well-suited for residential and light commercial applications, offering innovative features that cater to the specific demands of users, ensuring a comfortable indoor environment throughout the year.

One of the standout features of these units is their impressive energy efficiency ratings. Each model operates with advanced inverter technology, which allows the compressor to adjust its speed according to the cooling or heating demand. This technology not only provides more precise temperature control but also significantly reduces energy consumption compared to traditional air conditioning systems. The enhanced efficiency leads to lower utility bills and a reduced environmental footprint, making these units an eco-friendly choice.

The Friedrich MW12Y1F and MW09Y1F models are equipped with a powerful cooling capacity, suitable for medium to large spaces. The MR09Y1F and MR12Y1F, on the other hand, cater to slightly smaller areas while still delivering outstanding performance. All models come with multiple fan speeds and precise temperature controls, ensuring tailored comfort settings for any conditions.

Moreover, these air conditioning units come with advanced air filtration systems designed to improve indoor air quality. The multi-stage filtration captures dust, allergens, and other airborne particles, making the environment healthier, particularly for individuals with respiratory sensitivities.

User-friendly interfaces make these models easy to operate, with remote control functionalities that allow users to adjust settings from a distance. Some versions also offer smart home compatibility, enabling control via mobile apps or voice commands for enhanced convenience.

Durability is another hallmark of the Friedrich MW and MR series. Constructed with high-quality materials, these units are built to withstand various weather conditions while providing reliable performance throughout their lifespan.

In summary, the Friedrich MW12Y1F, MW09Y1F, MR09Y1F, and MR12Y1F stand out for their energy efficiency, advanced technology, user-friendly features, and robust build quality. These models contribute to comfortable living spaces while prioritizing health and energy savings, making them excellent choices for modern climate control needs.