Friedrich MW12Y1F Adjusting the Direction of AIR Circulation, Types of Air flow Direction Setting

Models: MR09Y1F MR12Y1F MW09Y1F MW12Y1F

1 46
Download 46 pages 28.65 Kb
Page 10
Image 10

ADJUSTING THE DIRECTION OF AIR CIRCULATION

Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit’s SET button. Horizontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers.

Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.

Vertical Air Direction Adjustment

Press the SET button (Fig. 6 O).

Each time the button is pressed, the air direction range will change as follows:

1 2 3 4 5 6 7

Types of Air flow Direction Setting:

1,2,3

:

During Cooling / Dry modes

4,5,6,7

:

During Heating mode

1,2,3,4,5,6,7 :

During Fan mode

The remote Control Unit’s display does not change.

Use the air direction adjustments within the ranges shown above.

The vertical airflow direction is set automatically as shown, in accordance with the type of operation selected.

During Cooling / Dry / Fan mode

:

Horizontal flow 1

During Heating mode

:

Downward flow 7

During AUTO mode operation, for the first minute after beginning operation, airflow will be horizontal 1; the air direction cannot be adjusted during this period.

RDANGER!

Never place fingers or foreign objects in- side the outlet ports, since the internal fan operates at high speed and could cause personal injury.

Always use the remote control unit’s SET button to adjust the vertical airflow louvers. Attempting to move them manually could result in improper operation; in this case, stop operation and restart. The louvers should begin to operate properly again.

During Cooling and Dry modes, do not move the vertical air direcion louvers outside their proper operating range for the mode (1 - 3) and into the fan region (4 - 7) ; using the louvers in the fan region will cause moisture to condense near the air outlet, and water may drop onto the floor. During the Cooling / Dry modes, if the louvers are operated outside the range 1 - 3 for more than 30 minutes, they will automatically return to position 3 range.

When used in a room with infants, chil- dren, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.

Right-Left Adjustment

Adjust the Right-Left louvers.

Move the Right-Left louvers to adjust air flow in the direction you prefer.

RDANGER!

When adjusting the Right-Left Louvers, it is necessary to stop the Air-Conditioner first and make sure that it stops completely before adjusting the direction.

knob

knobs (three places)

En-9

Page 10
Image 10
Friedrich MW12Y1F Adjusting the Direction of AIR Circulation, Vertical Air Direction Adjustment Press the SET button O