Specifications

Specifications

Electrical rating:

24 VAC (18-30 VAC)

DC Power: 3.0 VDC (2 “AA” batteries included)

1 amp maximum per terminal

3 amp maximum total load

Temperature control range: 45°F to 90°F (7°C to 32°C)

Accuracy: ± 1°F (± 0.5°C)

System configurations: 1-stage heat, 1-stage cool, heat pump, electric

Timing: Anti-short Cycle: 5 minutes

Backlight Operation: Battery for 5 seconds, hardwired for 10 seconds

Terminations: RC, RH, W, Y, B, O, GL, GH, C

Important Safety Information

WARNING!: Always turn off power at the main power supply before installing, cleaning, or removing thermostat.

This thermostat is for 24 VAC applications only; do not use on voltages over 30 VAC

Do not short across terminals of system control to test operation; this will damage your thermostat and void your warranty

All wiring must conform to local and national electrical and building codes

Do not use air conditioning when the outdoor temperature is below 50 degrees; this can damage your A/C system and cause personal injuries

Use this thermostat only as described in this manual

Package Contents/Tools Required

Package includes: RT5 thermostat on base, thermostat cover, wiring labels, screws and wall anchors, Installation, Operation and Application Guide

Tools required for installation: Drill with 3/16" bit, hammer, screwdriver