Testing the Thermostat

Testing the Thermostat

Once the thermostat is installed, it should be thoroughly tested.

CAUTION!: Do not energize the air conditioning system when the outdoor temperature is below 50 degrees. It can result in equipment damage or personal injury.

Cool Test

1.

Slide Mode switch to Cool mode.

 

2.

Adjust set temperature so it is 5 degrees below room temperature.

Cool Off Heat

3.

Air conditioning should come on within a few seconds. Status indicator may come on.

4.Adjust the set temperature 2 degrees above the room temperature and the A/C should turn off. There may be a fan delay on your system.

Cool TestHeat Test Note: There is a five minute time delay to protect the compressor after it turns off. To temporarily bypass the five minute delay, slide the Mode switch to OFF for 2 seconds and then back to Cool.

Heat Test

1.

Slide Mode switch to Heat mode.

 

2.

Adjust the set temperature so it is 5 degrees above the room temperature.

Cool Off Heat

3.

Heat should come on within a few seconds. Status indicator may come on.

4.Adjust the set temperature so it is 2 degrees below the room

temperature and the heat should turn off. There may be a fan delay on your system.

Manual backgroundManual background Note: For heat pumps, there is a five minute time delay to protect the compressor after it turns off. To temporarily bypass the five minute delay, slide the Mode switch to OFF for 2 seconds and then back to Heat.

(Testing the thermostat continued on Page 10)

9

Page 11
Image 11