4. Disassembly and Reassembly
4-1 Compressor Replacement Flow Chart
|
| Locate cause of defect |
|
|
| Release refrigerant |
|
|
| Disconnect electrical wiring |
|
|
| from compressor |
|
|
| Cut refrigerant lines |
|
|
| from compressor |
|
|
| Plug disconnected lines |
|
|
| Replace compressor |
|
Inspect electrical | Solder discharge line | Solder suction line | Use nitrogen gas |
wiring for defects, |
|
|
|
and terminals for |
|
|
|
correct and secure |
|
|
|
connections |
|
|
|
|
|
| Perform soldering function |
Y |
|
|
|
Problem? |
|
|
|
|
|
| Fill system with |
|
|
| nitrogen gas |
N |
|
|
|
|
|
| Check for leakage |
Corrective action |
|
| Y |
Check refrigerant oil level | Leakage? | ||
|
| ||
|
|
| N |
Release nitrogen gas?
YN
Low oil level?
Evacuate system
Add oil as necessary
Recharge system
Pinch and braze filling tube
FRIEDRICH AIR CONDITIONING CO. |