4-5.Disassembly and Reassembly Procedure(SP06A10/SP08A10)

Stop operating the air conditioner, and pull out the power cord before repair.

No.

Part Name

Procedures

Remarks

 

 

 

 

 

1

Ass’y Grille

1.Pull the Grille air inlet and Guard air filter out.

 

 

 

 

2.Remove the screw on the panel front.

 

 

 

 

3.Hold the lower part of panel with two hands

 

 

 

 

while pressing down on both sides of the lower

 

 

 

 

part of the cabinet, pull it forward by about

 

 

 

 

30mm,and then lift it up carefully for

 

 

 

 

removal.(Must un-connect the Displayer with

 

 

 

 

the controller inside.)

 

 

 

 

 

 

 

2

Ass’y Cabinet

1.Remove 2 screws on the both side of the

 

 

 

 

cabinet.

 

 

 

 

2.Pull the front part both side, and remove the

 

 

 

 

unit from the cabinet.

 

 

 

 

 

 

 

3

Ass’y Control

1.Remove the earth screw fixed on the cabinet.

 

 

 

 

2.Remove 3 screws fixed on the partition and

 

 

 

 

frame up.

 

 

 

 

3.Remove the screw fixed for the power cord.

 

 

 

 

4.Un-connect the motor wire and comp lead

 

 

 

 

wire, then take out the control box upward.

 

 

 

 

 

 

 

 

 

5