OCCURRENCE

POSSIBLE CAUSE

SOLUTION

DRYER

Dryer does not start.

Electrical power cord is not securely

Make sure the plug fits tightly in wall outlet.

 

 

 

 

plugged in or plug may be loose.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

House fuse blown or circuit breaker

Reset circuit breaker or replace fuse.

 

 

 

 

tripped.

Make sure electrical line is not overloaded and the dryer

 

 

 

 

 

 

 

 

 

 

 

 

is on a separate circuit.

 

 

 

 

 

 

 

 

 

 

 

 

Thermal limiter tripped.

Call authorized service person for replacement.

 

 

 

 

 

 

 

Dryer

runs

but won't

There are 2 house fuses in the dryer

Replace fuse.

heat.

 

 

 

circuit. If 1 of the 2 fuses is blown, the

 

 

 

 

 

 

drum may turn but the heater will not

 

 

 

 

 

 

operate.

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas supply valve is not open (gas models).

Check to make sure supply valve is open. See

 

 

 

 

 

 

INSTALLATION INSTRUCTIONS for procedure.

 

 

 

 

 

 

 

 

 

 

 

Dryer does not have enough air supply to

See INSTALLATION INSTRUCTIONS.

 

 

 

 

support the burner flame (gas models).

 

 

 

 

 

 

 

 

 

 

 

 

 

LP gas supply tank is empty or there has

Refill or replace tank.

 

 

 

 

been a utility interruption of natural gas

Dryer should heat when utility service is restored.

 

 

 

 

(gas models).

 

 

 

 

 

 

Drying

cycle

takes too

Lint screen is clogged with lint.

Make sure all lint has been removed from the dryer lint

long, outside of the dryer

 

 

screen before starting each cycle.

feels too hot or smells

 

 

 

 

 

 

 

 

 

 

hot.

 

 

 

Exhaust duct requirements have not been

Exhaust duct must be at least 4 inches in diameter and

 

 

 

 

met.

made of rigid or flexible metal.

 

 

 

 

 

 

When in place, the duct must have no more than two

 

 

 

 

 

 

90° bends and must not exceed length listed in

 

 

 

 

 

 

INSTALLATION INSTRUCTIONS.

 

 

 

 

 

 

 

 

 

 

Electric dryer is connected to a 208 volt

Drying time will be 20% longer than drying on a 240 volt

 

 

 

 

circuit.

circuit.

 

 

 

 

 

 

 

 

 

 

Drying procedures have not been

See Drying Procedures, page 10.

 

 

 

 

followed.

 

 

 

 

 

 

 

 

 

 

 

 

Outside exhaust hood or exhaust duct

Clean out any obstruction.

 

 

 

 

may be clogged or restricted.

 

 

 

 

 

 

 

 

Excessive wrinkling.

High humidity.

Use a dehumidifier near the dryer.

 

 

 

 

Dryer is overloaded.

Do not overload. See Drying Procedures, page 10.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Items left in dryer too long.

Remove items as soon as cycle ends.

 

 

 

 

 

 

 

 

 

 

Insufficient sorting of items.

See Drying Procedures, page 10.

 

 

 

 

 

 

 

 

 

 

Drying temperature too high.

Follow fabric care label instructions.

15

Page 15
Image 15
Frigidaire 134126300B important safety instructions Dryer