Frigidaire 316495063 Exhaust connection, Maximum duct length, equivalent feet 36.5 m, Ft. or m

Models: 316495063

1 24
Download 24 pages 20.25 Kb
Page 11
Image 11
120 equivalent feet (36.5 m).

Installation Instructions

NOTE: If you need to install ducts, note that the total duct length of 314x 10(8.2 x 25.4 cm) rectangular or 6(15.2 cm) diameter round duct should not exceed

120 equivalent feet (36.5 m).

Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.

NOTE: It is important that venting be installed using the most direct route and with as few elbows as possible. This ensures clear venting of exhaust and helps prevent blockages. Also, make sure dampers swing freely and nothing is blocking the ducts.

Exhaust connection:

The hood exhaust has been designed to mate with

a standard 314x 10(8.2 x 25.4 cm) rectangular duct.

If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6(15.2 cm) diameter duct.

Maximum duct length:

For satisfactory air movement, the total duct length of 314x 10(8.2 x 25.4 cm) rectangular or 6(15.2 cm) diameter round duct should not exceed 120 equivalent feet (36.5 m).

Elbows, transitions, wall and roof caps, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent lengths of all transitions and adaptors plus the length of all straight duct sections. The chart below shows you how to calculate total equivalent ductwork length using the approximate feet of equivalent length of some typical ducts.

 

EQUIVALENT

 

NUMBER

 

EQUIVALENT

DUCT PIECES

LENGTH

x

USED

=

LENGTH

 

 

 

Rectangular-to-Round

5 Ft. (1.5 m)

x

(

)

=

Ft. or m

 

 

 

 

Transition Adaptor*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall Cap

40

Ft. (12.2 m)

x

(

)

=

Ft. or m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90° Elbow

10

Ft. (3 m)

x

(

)

=

Ft. or m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45° Elbow

5 Ft. (1.5 m)

x

(

)

=

Ft. or m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90° Elbow

25

Ft. (7.6 m)

x

(

)

=

Ft. or m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45° Elbow

5 Ft. (1.5 m)

x

(

)

=

Ft. or m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roof Cap

24

Ft. (7.3 m)

x

(

)

=

Ft. or m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Straight Duct 6“ (15.2 cm)

1 Ft. (0.3 m)

x

(

)

=

Ft. or m

 

 

 

 

 

 

 

 

Round or 314“ x 10“

 

 

 

 

 

 

 

 

 

 

 

(8.2 x 25.4 cm) Rectangular

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Ductwork

=

Ft. or m

 

*IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have to be cut to fit, using the tin snips, in order to allow free movement of the damper.

Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any vent hood.

11

Page 11
Image 11
Frigidaire 316495063 warranty Exhaust connection, Maximum duct length, equivalent feet 36.5 m, Total Ductwork, Ft. or m