SERVICE CALL CHECK

Please check the following before calling for service:

Place one cup of water in a glass measuring cup in the microwave oven and close the door securely. Operate the microwave oven for one minute at HIGH 100%.

A

Does the microwave oven light come on?

YES ____

NO ____

B

Does the cooling fan work? (Put your hand on the louver above the Control Panel.)

YES ____

NO ____

C

Does the turntable rotate? (It is normal for the turntable to turn in either direction.)

YES ____

NO ____

D

Is the water in the microwave oven warm?

YES ____

NO ____

If “NO” is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit breaker. If they are functioning properly, CONTACT YOUR NEAREST ELECTROLUX AUTHORIZED SER- VICER.

A microwave oven should never be serviced by a “do-it-yourself” repair person.

NOTES

If time appearing in the display is counting down very rapidly, check Demonstration Mode on page 27 and cancel.

SPECIFICATIONS

AC Line Voltage:

Single phase 120V, 60Hz, AC only

 

 

AC Power Required:

1600W 14.2 amps. (for FGMV173QF, FGMV173QB/W/Q/M)

Output Power*:

1000 W

 

Frequency:

2450 MHz (Class B/Group2)**

 

Outside Dimensions:

29

7/8”(W) x 16 13/32”(H) x 15

1/32”(D)

Cavity Dimensions:

20

15/16”(W) x 9 7/16”(H) x 14

13/32”(D)

Microwave oven Capacity***:

1.7 Cu.Ft.

 

Cooking Uniformity:

Turntable

 

Weight:

Approx. (net) 61.7 lb, (gross) 28.0 lb

Work/Night Light:

2 bulbs 30w each (incandescent light bulbs)

Oven Light:

1 bulb 30w (incandescent light bulbs)

*The International Electrotechnical Commission’s standardized method for measuring output wattage. This test method is widely recognized.

**This is the classification of ISM (Industrial, Scientific and Medical) equipment described in the International Standard CISPR11.

***Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food is less. In compliance with standards set by:

FCC

- Federal Communications Commission Authorized.

DHHS

- Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter J.

NHW

- Department of National Health and Welfare of Canada.

 

- This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.

 

- This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. for use in

 

USA or Canada.

32

Page 32
Image 32
Frigidaire FGMV175QF, FGMV175QW important safety instructions Service Call Check, Specifications