Before You Call

Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.

OCCURRENCE

SOLUTION

 

 

 

 

Air conditioner will not operate.

Wall plug disconnected. Push plug firmly into wall outlet.

 

 

 

 

 

 

 

Plug Current Device Tripped. Press the RESET button.

 

 

 

 

 

 

 

House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.

 

 

 

 

 

 

 

Control is OFF. Turn Control ON and set to desired setting.

 

 

Air from unit does not feel cold

Room temperature below 60°F (16°C). Cooling may not occur until room temperature rises above

enough.

60°F (16°C).

 

 

 

Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil.

 

 

 

 

 

 

 

Reset to a lower temperature.

 

 

 

 

 

 

 

Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to

 

 

 

restart when set in the COOL mode.

 

 

Air conditioner cooling, but room

Outdoor temperature below 60 O F (16 OC). To defrost the coil, set FAN ONLY mode.

is too warm - ice forming

 

Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY

on cooling coil behind decorative

mode.

front

Temperature is set too low for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then,

 

 

 

 

 

 

set temperature to a higher setting.

 

 

 

Air conditioner cooling, but room

Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.

is too warm - NO ice forming on

 

Temperature is set too high. Set temperature to a lower setting.

cooling coil behind decorative

 

Air directional louvers positioned improperly. Position louvers for better air distribution.

front.

 

 

 

 

 

 

 

Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in

 

 

 

front of unit.

 

 

 

 

 

 

 

Doors, windows, registers, etc. open - cool air escapes. Close doors, windows, registers, etc.

 

 

 

 

 

 

 

Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling,

 

 

 

floor and furniture.

 

 

 

Air conditioner turns on and off

Dirty air filter - air restricted. Clean air filter.

rapidly.

 

 

 

Outside temperature extremely hot. Set FAN speed to a faster setting to bring air through cooling coils

 

 

 

 

 

 

more frequently.

 

 

Noise when unit is cooling.

Air movement sound. This is normal. If too loud, set to lower FAN setting.

 

 

 

Window vibration - poor installation. Refer to installation instructions or check with installer.

 

 

Water dripping INSIDE when

Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to

unit is cooling.

installation instructions or check with installer.

 

 

Water dripping OUTSIDE when

Unit removing large quantity of moisture from humid room. This is normal during excessively humid

unit is cooling.

days.

 

 

Room too cold.

Set temperature too low. lncrease set temperature.

If These Solutions Fail, Call 1-800-944-9044 For Frigidaire Service.

2009 Electrolux Home Products, Inc.

All rights reserved.

11

 

 

 

 

 

 

Page 11
Image 11
Frigidaire FRA064VU1 important safety instructions Before You Call, Occurrence Solution

FRA064VU1 specifications

The Frigidaire FRA064VU1 is a compact, energy-efficient window air conditioner designed to provide optimal comfort in small to medium-sized rooms. Offering a cooling capacity of 6,000 BTUs, it's an ideal solution for areas up to 250 square feet, such as bedrooms, home offices, or smaller living spaces.

One of the standout features of the FRA064VU1 is its user-friendly electronic controls. The clear LED display and easy-to-push buttons make it accessible for everyone. With multiple cooling and fan speeds, users can easily customize their experience to find the perfect temperature. The unit also comes equipped with a programmable timer, allowing you to set it to turn on or off at specific times, contributing to energy savings and convenience.

The FRA064VU1 incorporates advanced technologies to enhance energy efficiency. It is ENERGY STAR certified, meaning it meets strict energy efficiency guidelines set by the U.S. Environmental Protection Agency. This not only helps reduce your electricity bills but also lowers your carbon footprint. Moreover, the unit features a powerful fan and a quiet operation mode, ensuring that it delivers a refreshing cool breeze without causing significant noise disruption.

Another notable characteristic of this air conditioner is its easy installation process. The unit comes with a versatile window mounting kit, allowing for a secure fit in various window sizes. The adjustable side panels help in achieving a snug fit, enhancing the overall cooling capability. Additionally, the unit includes a removable, washable filter designed to capture dust and allergens, promoting better air quality while extending the lifespan of the air conditioner.

The sleek, modern design of the Frigidaire FRA064VU1 blends seamlessly with any interior decor, and its lightweight frame makes it easy to install and remove when necessary. With its combination of performance, energy efficiency, and user-friendly features, the Frigidaire FRA064VU1 stands out as an excellent choice for those seeking reliable cooling solutions in a compact package. Whether you're looking to beat the summer heat or simply want to maintain a comfortable indoor environment, this air conditioner delivers impressive results without compromising on style or efficiency.