Frigidaire MWTK(P)30K, MWTK(P)27K Electrical Outlet Location, Exhaust Duct Assembly, Illustration

Models: MWTK(P)30K MWTK(P)27K

1 12
Download 12 pages 6.03 Kb
Page 3
Image 3
ELECTRICAL OUTLET LOCATION

Installation Instructions

Illustration 2

ELECTRICAL OUTLET LOCATION

Outlet should NOT be in the shaded area as indicated on Illustration 2

NOTE 1:

If the Depth (C) dimension is greater than 21” (53.3 cm), the outlet location may be in any area on the rear wall.

NOTE 2:

The floor of the opening should be constructed of plywood strong enough to support the weight of the oven and floor load (approximately 100 pounds). The floor should be level for proper operation of the oven. Be sure to check the local building code as it may require that the opening be enclosed with side, ceiling and rear partition. The proper functioning of the oven does not require the enclosure.

Flanges

Screw A

Exhaust Dust

Assembly

Screw A

Illustration 3

EXHAUST DUCT ASSEMBLY

1.Place the Exhaust Duct in the opening. When the Exhaust Duct Assembly is in the opening correctly, the flanges will be tightly against the lower edge of the opening. See Illustration 3.

2.Secure the Exhaust Duct Assembly with the two screws A.

IMPORTANT: Secure screws in outer hole.

3

Page 3
Image 3
Frigidaire MWTK(P)30K Electrical Outlet Location, Exhaust Duct Assembly, Installation Instructions, Illustration