18

INSTALLATION

Attaching Grate To Base Assembly

OPERATING HEATER (THERMOSTAT-CONTROLLED MODELS)

For Your Safety Read Before Lighting

Lighting Instructions

INSTALLATION

Continued

ATTACHING GRATE TO BASE ASSEMBLY

Locate the two slots in the front of the base assembly. Carefully slide the decorative grate into these slots (see Figure 33).

Grate

Slots in Base

Figure 33 - Attaching Grate to Base Assembly (Logs and Base Will Vary According to Model)

ADDING LAVA ROCK

Place lava rock around base of heater. Be sure not to cover the control knobs or air inlet openings on the front of heater.

OPERATING HEATER

THERMOSTAT-CONTROLLED MODELS

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

WARNING:

• If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fire- place will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

• You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burn- ing logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

For..com

108114

Page 18
Image 18
Desa INTERNATIONAL UNVENTED (VENT-FREE) GAS LOG HEATER Operating Heater, Attaching Grate to Base Assembly

INTERNATIONAL UNVENTED (VENT-FREE) GAS LOG HEATER specifications

The Desa International Unvented (Vent-Free) Gas Log Heater stands as a remarkable solution for those seeking an efficient and aesthetically pleasing heating option for their homes. Recognized for its innovative design and advanced technology, this heater offers numerous benefits that cater to both functionality and style.

One of the main features of the Desa gas log heater is its vent-free design. This characteristic eliminates the need for ductwork or exhaust systems, allowing for easy installation in various locations, including living rooms, bedrooms, or recreational areas. With no external venting required, homeowners can enjoy increased flexibility in placement while saving on installation costs and labor. Moreover, the heater can fit seamlessly into existing fireplaces, creating a cozy ambiance without the need for traditional firewood.

Another standout feature of the Desa vent-free gas log heater is its exceptional energy efficiency. Utilizing infrared technology, the heater converts a high percentage of gas to heat, warming spaces quickly and reducing energy consumption. The unit is designed to operate with natural gas or propane, offering versatility depending on the homeowner's fuel preferences.

Safety is a top priority in the design of the Desa gas log heater. Equipped with an automatic shut-off system and an oxygen depletion sensor, the heater ensures secure operation by shutting down in case oxygen levels drop too low. This added safety feature provides peace of mind for families, allowing for safe use even during extended periods of operation.

Aesthetically, the Desa International gas log heater does not compromise on style. With an array of realistic log designs and finishes, homeowners can choose a heater that complements their interior decor perfectly. The unit’s flame effects mimic traditional wood-burning fires, enhancing the warm ambiance of any room.

In conclusion, the Desa International Unvented (Vent-Free) Gas Log Heater offers a unique combination of efficiency, safety, and aesthetics. Its vent-free design allows for flexible installation, while infrared heating technology ensures quick warmth and energy savings. Coupled with enhanced safety features and an attractive appearance, this gas log heater provides a practical and stylish heating solution for any home.