OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB

28

OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB (THERMOSTAT-CONTROLLED MODELS ONLY)

For Masonry and Factory-Built Metal Fireplace

OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB

(THERMOSTAT-CONTROLLED MODELS ONLY)

FOR MASONRY AND FACTORY-BUILT METAL FIREPLACE

If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.

The thermostat sensing bulb is located on the left side of the base assembly. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applica- tions. For positioning the thermostat sensing bulb elsewhere, an adhesive-backed mounting clip is available.

1.Locate the gas valve assembly and thermostat sensing bulb (see Figure 49).

2.Gently pull thermostat sensing bulb free from the retaining clamp.

IMPORTANT: Do not force or bend the thermostat sensing bulb or capillary.

3.The thermostat sensing bulb may be located to the lower right front side of fireplace. Determine location of sensing bulb, but do not mount sensing bulb until step 4. If you have a masonry fireplace, see Figure 51 for location.

If you have a factory-built metal fireplace, see Figure 52 for location.

If your fireplace has glass doors, position sensing bulb directly behind door gap on right bottom side (see Figure 53).

4.The mounting clip must be a minimum of 3" from bottom of fireplace to prevent crimping of capillary. Once you have de- cided on a location, clean the area thoroughly. Remove the pa- per backing from the adhesive on back of mounting clip. Press the clip into the new location so that the thermostat sensing bulb will be positioned vertically with the capillary at the bottom (see Figure 54). Slide the thermostat sensing bulb into the clip.

IMPORTANT: Do not crimp capillary.

Thermostat Sensing Bulb

Adhesive-

backed (THERMOSTAT-CONTROLLED MODELS ONLY) Mounting

Clip

Figure 50 - Adhesive-backed Figure 51 - Locating Thermostat

Mounting ClipSensing Bulb on Masonry Fireplace

Thermostat Sensing Bulb

Thermostat Sensing Bulb

 

Adhesive-

 

backed

 

Mounting

Adhesive-

Clip

 

backed

 

Mounting

 

Clip

Glass

 

Figure52 -LocatingThermostat Figure53 - InstallingThermostat

Sensing Bulb on Factory-built

Sensing Bulb behind Glass

Metal Fireplace

Doors

Thermostat Sensing Bulb

 

Adhesive-

 

backed

 

Mounting

Capillary

Clip

 

 

Do Not

 

Crimp

 

Capillary

Figure 54 - Positioning the Thermostat Sensing Bulb in the Vertical Position with the Capillary at the Bottom

Thermostat Sensing Bulb

Retaining

Gas Valve

Assembly

 

Clamp

 

 

Figure 49 - Location of Gas Valve Assembly and Thermostat

Sensing Bulb

FOR MASONRY AND FACTORY-BUILT METAL FIREPLACEManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background