OCCURRENCE POSSIBLE CAUSE SOLUTIONWATER
Wash load too wet after Washer is overloaded. Donotoverioadwasher.See Washing Procedures.
spin. Loadis out of balance. Rearrangeload to allow proper spinning.
Drain hose iskinked. Straighten drain hose.
Water does not enter Water supply is not adequate in area. Checkanotherfaucetinthehouse. Waituntiiwater
washer or it entersslowly, supplyand pressureincrease.
Water supplyfaucets are not completelyopen. Fullyopen hot and cold faucets.
Water is being usedelsewhere in thehouse. Water pressure must beat least30 psi(260 kPa).
Avoid running water elsewhere while washer is
filling.
Water inlet hosesare kinked. Straighten hoses.
Water level does not cover Improperwater levelselection (formodels with Selecthigher water level/load size.
load. water level/load sizecontrol).
Washer is overloaded. Do not overload washer. When control is setat
highestfill level,dry load levelshouldnot behigher
than top row of circularholes in wash tub.
Warm or hot water is not Hot waterheater isset too lowor isa distance Measure hot water temperature at nearbyfaucet
hot enough, from washer, with candy or meat thermometer. Water
temperatureshould beatleast 130°F(70°C). Adjust
water heater as necessary.
Hotwaterisbeing usedelsewhereinthehouse. Avoid using hot water elsewhere before or during
washer use.There maynot be enough hot water
availablefor proper cleaning. If problem persists,
your hot water system may be unableto support
morethan 1 use at atime.
Water in washer does not Drain hoseiskinked orclogged. Cleanand straighten the drain hose.
drain or drains slowly.
Water leaks. Fillhose connection atfaucet or washer. Checkand tighten hoseconnections. Installrubber
sealingwashers provided.
Housedrain pipesare clogged. Unclog drainpipes. Contact plumber if necessary.
Oversudsing. Useless detergent.
Incorrect wash and rinse Hot and cold water hoses areconnected to Connect hot water hoseto hot water faucet and
temperatures, wrong supply faucets, cold water hose to coldwater faucet.
Water is entering washer Drainhose standpipe isincorrect height.
but tub does not fill. Standpipe must be a minimum of 33" (83.82 cm)
high to prevent siphoning. See INSTALLATION
INSTRUCTIONS.
11