![](/images/backgrounds/149353/149353-2012x1.png)
Chapter 2 — Getting Started
Preset voltage setting for MSR
1.The MSR default setting is ISO Track 1 & 2. (For customized track settings, advise the manufacturer before production.)
2.In event of any requirement to change the setting of the MSR, run Setting utility in the driver CD provided in the accessory package.
3.The normal swiping card speed of the MSR is 10 to 100 cm/sec. (based on the ISO 7812 standard).
Limitations
Connector with | Location | Average current | Pack current | |
Voltage Output | ||||
|
|
| ||
COM 1 for External input | LCD Panel Side | DC 5V / 0.5A, | DC 5V / 1A, | |
device interface | DC 12V / 0.5A | DC 12V / 0.5A | ||
| ||||
COM 2 for Touch Panel | LCD Panel Side | DC 5V / 0.3A | DC 5V / 0.5A | |
interface | ||||
|
|
| ||
COM 3 for extension | LCD Panel Side | DC 5V / 0.3A, | DC 5V / 0.5A, | |
interface (9th PIN of | (On Mother Card) | DC 12V / 0.5A | DC 12V / 1A | |
COM 4 for extension | Bottom side (On | DC 5V / 0.3A, | DC 5V / 0.5A, | |
interface (9th PIN of | Interface Board) | DC 12V / 0.5A | DC 12V / 1A | |
COM 5 for Pole Display | Bottom side (On | DC 5V/ 1A | DC 5V / 1A, | |
Interface Board) | DC 12V/ 1A | DC 12V / 1A | ||
COM 6 for Cash Drawer | Internal connector | DC 12V / 1A | DC 12V / 1A, | |
driving (Pulse) | DC 24V / 1A | DC 24V / 1A | ||
| ||||
DC 12V Powered USB for | Bottom side (On | DC 12V / 1.5A | DC 12V / 2.5A | |
peripherals | Interface Board) | |||
|
| |||
DC 24V Powered USB for | Bottom side (On | DC 24V/ 1.5A | DC 24V / 2A | |
peripherals | Interface Board) | |||
|
| |||
*2nd LCD Monitor Power | Bottom side (On | DC 12V / 1.5A | DC 12V / 2.5A | |
Connector (DC Plug) | Interface Board) | |||
|
| |||
*DC 24V Printer Power | Bottom side (On |
|
| |
Connector (Hosiden | DC 24V/ 1.5A | DC 24V / 2A | ||
Interface Board) | ||||
3PIN) |
|
| ||
|
|
|
Note:
•None of the COM Port current loading should exceed DC 5V/3A+ DC 12V/2A.
•DC 12V /24V powered USB should not be used with 12V DC plug and 24V Hosiden at the same time.
•When 2nd Display uses 12V DC plug, the thermal printer can NOT use the 24V Hosiden simultaneously.