Problem | Probable Causes |
| A. The |
Fryer stops heating | and displays , or the |
with heat indicator | contactor has failed. |
ON. |
|
B. Tilt switch is up or defective.
Corrective Action
A. The fact that the heat indicator is ON indicates that the controller is functioning properly and is calling for heat. The
Call FASC.
B.Make sure that the elements are completely lowered.
5.2.2 Error Messages and Display Problems
Problem | Probable Causes | |
Display is in wrong |
| |
temperature scale | Incorrect display option programmed. | |
(Fahrenheit or | ||
| ||
Celsius). |
|
Open drain valve, bad
Display shows . thermostat or problem with latching
circuitry.
Display shows | Fryer is more than 21°F (12°C) above |
. setpoint. |
Corrective Action
CM III.5 computers may be programmed to display in either Fahrenheit or Celsius. To change from one to another, press the
Program Mode Switch . Code will appear in the left display. Enter code 1658. The computer will toggle the display to either Fahrenheit or Celsius.
Verify that the drain valve is fully closed. The fryer will not function if the drain valve is not fully closed. If the drain valve is fully closed, the problem is either the