Problem | Probable Causes | Corrective Action | |
|
| This in an indication of a malfunction | |
Display shows . | Frypot temperature is more than 410°F | in the temperature control circuitry, | |
(210°C) or, in CE countries, 395°F | including a failure of the | ||
| (202°C). | thermostat. Shut the fryer down | |
|
| immediately and call FASC. | |
|
| This display is normal when the fryer | |
|
| is first turned on and may appear for a | |
|
| short while if a large batch of frozen | |
|
| product is added to the frypot. If the | |
|
| display never goes out, the fryer is not | |
|
| heating. Look for a decimal in the | |
Display shows . | Frypot temperature is more than 21°F | LED display between digits 1 and 2. | |
If the decimal is present, the computer | |||
(12°C) below setpoint. | |||
| is calling for heat and is functioning | ||
|
| ||
|
| properly. See Fryer Does Not Heat in | |
|
| Control and Heating Problems | |
|
| (Section 5.2.1). If the decimal is not | |
|
| present, the computer is not calling for | |
|
| heat and may be malfunctioning. | |
|
| Turn the fryer off and call FASC. | |
|
| This indicates a problem within the | |
Display shows . | Problem with the temperature measuring | temperature measuring circuitry that is | |
beyond the scope of operator | |||
| circuitry including the probe. | troubleshooting. Shut the fryer down | |
|
| ||
|
| and call FASC. | |
|
| The CM III.5 computer may be | |
|
| programmed for constant temperature | |
Frypot temperature is | Computer is programmed for constant | display or countdown timer display. | |
To change setting press the Program | |||
displayed constantly. | temperature display. | ||
Mode Switch . Code will appear | |||
|
| ||
|
| in left display. Press 1, 6, 5 and L to | |
|
| toggle between these display options. | |
5.2.3 Basket Lift Problems |
|
Problem | Probable Causes | Corrective Action |
Basket lift movement |
| Apply a light coating of Lubriplate or |
is noisy, jerky, or | Lack of lubrication on basket lift rods. | similar lightweight white grease to the |
erratic. |